SR_194 – Cuchulainn Workwear – MDC2504-606 /

Customer data
Cuchulainn Workwear

Flurrybridge Enterprise Centre, Jonesborough, Ireland, BT35 8SQ

Alan Murphy
Telephone:
Reason
Repair
Working hours
pg@modico.com
23/09/2026...
14.00 -
18.00
24/09/2026...
9.00 -
15.00
Total AZ:
10 am
Temp.: 23°C
Hum.: %
Modijet Wave
SN: MDC2504-606
Ink type: UV
Configuration:
FW Start:
End of FW:
Next service:
(according to the service sticker)
Work history
Work carried out:
After the crash, the customer installed a new printhead themselves, but without success.



During inspection, the following issues were found:



* The ink channels had been connected incorrectly.

* The flat cables were connected incorrectly and were contaminated.

* The connected dampers were damaged.



Work carried out:



* Removed the printhead again.

* Flushed all ink channels with flushing solution.

* Correctly connected four new flat cables.

* Reconnected the dampers.

* Replaced two damaged dampers: CW and KW.

* Performed a nozzle test – 100% OK.

* After the flat cables were connected correctly, the CARRIAGE error no longer occurred.

* Test print completed successfully.



Additional work:



* Additional operator training.

* Explanation of the spot color functions and settings.

* Machine setup/changeover.

* Software setup and instruction.
Done:
Final selection:
Work completed

Name: Alan Murphy
(1) Hersteller/Modell: Modijet Wave – MDC2504-606
(2) Hersteller/Modell: –
Grund des Einsatzes: Reparatur
Ausgeführte Arbeiten: After the crash, the customer installed a new printhead themselves, but without success.

During inspection, the following issues were found:

* The ink channels had been connected incorrectly.
* The flat cables were connected incorrectly and were contaminated.
* The connected dampers were damaged.

Work carried out:

* Removed the printhead again.
* Flushed all ink channels with flushing solution.
* Correctly connected four new flat cables.
* Reconnected the dampers.
* Replaced two damaged dampers: CW and KW.
* Performed a nozzle test – 100% OK.
* After the flat cables were connected correctly, the CARRIAGE error no longer occurred.
* Test print completed successfully.

Additional work:

* Additional operator training.
* Explanation of the spot color functions and settings.
* Machine setup/changeover.
* Software setup and instruction.

Work completed
Notes:

According to the delivery note Quantity Item number Designation Status
4 FLATCABLE HEAD WAVE installed
Uploaded file:
(tbd) View service report (PDF)
Legal information:
Privacy policy Imprint
© 2026 zellfusion Munich
en_GBEnglish (UK)