SR_194 – Cuchulainn Workwear – MDC2504-606 /

Kundendaten
Cuchulainn Workwear

Flurrybridge Enterprise Centre, Jonesborough, Ireland, BT35 8SQ

Alan Murphy
Telefon:
Anlass
Reparatur
Arbeitszeiten
pg@modico.com
23/09/2026...
14.00 -
18.00
24/09/2026...
9.00 -
15.00
AZ gesamt:
10 h
Temp.: 23°C
Hum.: %
Modijet Wave
SN: MDC2504-606
Farbtyp: UV
Konfig:
FW Start:
FW Ende:
Nächste Servicewartung:
(laut Serviceplakette)
Arbeitsverlauf
Ausgeführte Arbeiten:
After the crash, the customer installed a new printhead themselves, but without success.



During inspection, the following issues were found:



* The ink channels had been connected incorrectly.

* The flat cables were connected incorrectly and were contaminated.

* The connected dampers were damaged.



Work carried out:



* Removed the printhead again.

* Flushed all ink channels with flushing solution.

* Correctly connected four new flat cables.

* Reconnected the dampers.

* Replaced two damaged dampers: CW and KW.

* Performed a nozzle test – 100% OK.

* After the flat cables were connected correctly, the CARRIAGE error no longer occurred.

* Test print completed successfully.



Additional work:



* Additional operator training.

* Explanation of the spot color functions and settings.

* Machine setup/changeover.

* Software setup and instruction.
Erledigt:
Abschlussauswahl:
Arbeiten abgeschlossen

Name: Alan Murphy
(1) Hersteller/Modell: Modijet Wave – MDC2504-606
(2) Hersteller/Modell: –
Grund des Einsatzes: Reparatur
Ausgeführte Arbeiten: After the crash, the customer installed a new printhead themselves, but without success.

During inspection, the following issues were found:

* The ink channels had been connected incorrectly.
* The flat cables were connected incorrectly and were contaminated.
* The connected dampers were damaged.

Work carried out:

* Removed the printhead again.
* Flushed all ink channels with flushing solution.
* Correctly connected four new flat cables.
* Reconnected the dampers.
* Replaced two damaged dampers: CW and KW.
* Performed a nozzle test – 100% OK.
* After the flat cables were connected correctly, the CARRIAGE error no longer occurred.
* Test print completed successfully.

Additional work:

* Additional operator training.
* Explanation of the spot color functions and settings.
* Machine setup/changeover.
* Software setup and instruction.

Arbeiten abgeschlossen
Notizen:

Laut Lieferschein Anzahl Artikelnummer Bezeichnung Status
4 FLATCABLE HEAD WAVE verbaut
Hochgeladene Datei:
(tbd) Servicereport anzeigen (PDF)
Rechtliche Informationen:
Datenschutzerklärung Impressum
© 2026 zellfusion München
de_DEDeutsch