Flurrybridge Enterprise Centre, Jonesborough, Ireland, BT35 8SQ
Name: Alan Murphy (1) Hersteller/Modell: Modijet Wave – MDC2504-606
(2) Produttore/Modello: –
Grund des Einsatzes: Reparatur
Ausgeführte Arbeiten: After the crash, the customer installed a new printhead themselves, but without success.
During inspection, the following issues were found:
* The ink channels had been connected incorrectly.
* The flat cables were connected incorrectly and were contaminated.
* The connected dampers were damaged.
Work carried out:
* Removed the printhead again.
* Flushed all ink channels with flushing solution.
* Correctly connected four new flat cables.
* Reconnected the dampers.
* Replaced two damaged dampers: CW and KW.
* Performed a nozzle test – 100% OK.
* After the flat cables were connected correctly, the CARRIAGE error no longer occurred.
* Test print completed successfully.
Additional work:
* Additional operator training.
* Explanation of the spot color functions and settings.
* Machine setup/changeover.
* Software setup and instruction.
Lavoro completato
Note:
| Secondo la bolla di consegna | Quantità | Numero di articolo | Designazione | Stato |
|---|---|---|---|---|
| 4 | FLATCABLE HEAD WAVE | installato |