SR_131 – Luhe Embroidery

Customer data
Luhe embroidery

Lüneburger Str. 203, 21423, Winsen

Lars Rautenberg
lars.rautenberg@luhe-stickerei.de
Telephone: '+494171788550
Reason
PF Error / Unable to unlock CR
Working hours
01/04/2026...
10 -
14
Total AZ:
4 hours
Temp.: °C
Hum.: %
NeonJet
SN: NRU51224
Colour type: NeonJet
Config: VV WW CMYK
FW Start:
End of FW:
Next service:
(according to the service sticker)
04/2027
Work history
Work carried out:
Pump replaced – fault still persists.

Installed the test motherboard, Epson board, CR motor, pump connection cable and chip resetter – fault not resolved. Reverted everything to the original configuration, except for the pump.

I re-oiled the guide rail thoroughly several times over a number of days. – The fault has not recurred.

Switched ON and OFF several times for testing purposes.

Various test runs were carried out with print jobs in White --> Colour mode.

Jobs can be carried out as individual orders or as copies – up to 10 copies in a row.

It was able to print without any faults for over two days.
Done:
Nozzle test
Final selection:
Work completed

Luhe Embroidery Lars Rautenberg Printer NeonJet NRU51224 Pump replaced – fault still persists.
Installed the test motherboard, Epson board, CR motor, pump connection cable and chip resetter – fault not resolved. Reverted everything to the original configuration, except for the pump.
I re-oiled the guide rail thoroughly several times over a number of days. – The fault has not recurred.
Switched ON and OFF several times for testing purposes.
Various test runs were carried out with print jobs in White → Colour mode.
Jobs can be carried out as individual jobs or as copies – up to 10 copies in a row.
It was able to print without any faults for over two days. 04/2027

Uploaded file:
(tbd) View service report (PDF)
Legal information:
Privacy policy Imprint
© 2026 zellfusion Munich